ASI Provides H2S On-Line Process Analyzer General Purpose ASTM Method Series 1100
 

Home|Products|Quote Request|Contact

Analyzers for Gas
H2S in Gas & LPG's
CO2 in Gas
Total Sulfur in Gas & LPG's

 
Houston Atlas Tracor ONIX  Thermo

 
H2S & Total Sulfur in Gas &  LPG's
Analyzers for Liquids
VOC's in Water
Oil in Water
H2S in Liquids
Analyzer Accessories
Fugitive Emission Units

 
H2S Sensing Tapes & Cassette
Sensors Air Quality
Smart Sensors
Personal H2S Sensor
Monitors Air Quality
Cabinet NEMA4 Mounting
Panel Mounting
Rack Mounting
Contact Us
Quote Request
Sales
Technical Service
Accounting

Total Sulfur Analyzer Explosion Proof Tape Method Series 1700
 
Page Two/Tech Data
(.pdf) Brochure
Request Quote for H2S On-Line Process Analyzer General Purpose ASTM Method
 
H2S Analyzer Features

 
Total Sulfur Analyzer Explosion Proof Tape Method Series 1700
ASTM Method References
Interference Free Detection
Continuous Analysis
Automatic Calibration
PPB, PPM, Thru % Ranges
General Purpose
Direct Read LCD
Single LED Light Source
Digital Electronics
Duel Processor Power 100% Analysis
18-bit A/D Conversion For Faster Response, Lower Detection Limits & Less Tape Consumption
Fault Diagnostics
Specific for Sulfur Only

Description

The petrochemical, gas processing, and gas pipeline industry has required an accurate, dependable, low maintenance, and cost-effective sulfur analyzer for quality and process control purposes. With over twenty-five years of experience in developing and manufacturing sulfur analyzers and associated parts and supplies, Analytical Systems International (ASI) has met these requirements with their proven microprocessor based analyzer. The Model 1700 System measures total sulfur by hydrogenation similar to that as described in ASTM Method D3031, D4084-82, D4468-85 and 4045-81. The sulfur sample is precisely metered into a continuous flowing stream of hydrogen gas. The sample and hydrogen are
heated in the furnace up to 1,315° C resulting in thermal cracking of the sulfur that are reduced to short chain hydrocarbons. These reactions result in the formation of H2S. After complete humidification of the sample, the H2S comes in direct contact with the lead acetate tape and produces a darkening of lead sulfide that is immediately measured by the photodiode/LED optics and rate-of-reaction digital electronics to provide an accurate and reproducible total sulfur analysis with PPB or PPM sensitivity up to 100%. The LCD display provides the current reading, any alarm condition, procedure prompts (i.e., calibration procedure), and failure indicators (local and remote capability). Quality materials are selected for their compatibility and utilized through fabrication. Special attention is given to wetted parts that come in contact with the process stream and are selected to be non-reactive with H2S.

 
Page Two/Tech Data
(.pdf) Brochure
Request Quote for H2S On-Line Process Analyzer General Purpose ASTM Method